ac/dc power | 380V,220V,410V |
specifications |
Input voltage | Three phase AC380V±15% or single phase AC220V±15% 50HZ 60HZ |
Output rated value | Output current :0-20000A optional 100%continuously adjustable designed by your requirements Output voltage :0-400V optional 100%continuously adjustable designed by your requirements |
Output range | Output voltage:0~rated value. (no limited) Output current : 0~rated value.( no limited) |
Efficiency | More than 90% |
Control mode | PWM Pulse control |
Cool mode | Forced by air cooling |
Voltage stability | within1% |
Current stability | within1% |
Control accuracy | Rated value within±1% |
Operation mode | Constant voltage , Constant current , output adjustment , ON/OFF , soft start and so on .Designed by your requirements |
Work load | 100% full load continuous running , If more than 1, 000 meters above sea level, it will be reduced load operation |
Working condition | Indoors better with ambient Temperature range from -10 °C to 40 °C is good for device , Less than 90% humidity(when ambient temperature is 20°C±5°C) |
Display | Digital meters or touch screen , Ampere hour meter , timer alarm , etc . Designed by your requirements |
Signal interface | PLC 4-20mA, 0~5V, 0~10V , RS485 or RS232 Designed by your requirements |
Complete functions | The self-protection function of over current , short circuit, overheating , phase lack , etc .Easy to maintain |
Warranty | At least One year from delivery against manufacturing defects, material defects and workmanship fails. Warranty does not cover mishandling, misuse and any operation outside working conditions |
Reasonable design , more safe and durable , separate from the harsh environment |