Price : | Price Negotiable |
Minimum Order : | 1 (set) |
Product Status : | New |
Sample Available : | yes |
Shipment Terms : | fob,cfr,cif,Negotiable |
Payment Mode : |
T/T,L/C,cash |
Categories : | Machinery, Purifier, Filter & Water Process |
Posted By : | Chong Qing Zhong Neng Oil Purifier Manufacture Co.,ltd |
Breakdown Voltage (Dielectric) | 80 KV |
Moisture (water content) | 3 PPM |
Gas Content | 0.1% |
Impurities Degree (Filtration precision) | 1u |
Application:
Series ZYD Double-stage vacuum transformer oil purifier is special for treating the new and old transformer oil, mutual oil, switch oil. Comparing with the single stage type, this machine adopts the double stages vacuum system, which can improve the machine working vacuum value highly, so it can remove the water, gas and impurities in transformer oil high-efficiently, increasing and maintain the oil's dielectric strength and quality of oil, make sure the electric device running safely. It is mainly used for purifying the insulating oil in all kinds of large power equipments which are above110KV.
Meanwhile, as the bridge-type vacuum linking system, Series ZYD oil purifier can be used as independent vacuum source with functions of vacuum drying, vacuum filling oil.
1. PH of treat oil ≥5.5 2. Acid value ≤0.03mgkoH/g
3. Flash point ≥145℃ 4. Anti-pressure≥80KV
5. Dielectric loss: Dielectric loss: tg δ (90°C)% ≤0.001
6. High vacuum: high point-vacuum ≤5Pa; working-vacuum ≤35Pa
7. High absorption speed: absorption speed power ≥333L/Sr.
8. Duplex 3D stereo-evaporation, eliminating the liquid water quickly
9. UK G technology, by which the trace water that is show chain, such as dissolved water, can be removed effectively
10. Instinctively removing impurities system filtering through the double FH trapezoidal network and absorbing by high polymer without mechanical power
11. Argon fiber infrared heating system that can make the oil contain zero sum of ethyne after the treatment.
12. Advanced infrared oil level control system and pressure protection device make operation simple and safe.
13. The equipment is installed with auto alarming system, it will give out alarm and stop the whole machine when electrical motor is overloaded, vacuum pump and oil pump overloaded, heater overloaded and pressure abnormal.
14. Adopt a trinity of interlocked preventive device.
15. AdoptGermany’s 3UG3 Phase Relay.
16. It can purify transformer oil on-line without cutting off the power
17. The machine with PLC can operate automatically. (optional)
Technical Data
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working vacuum | MPa | -0.08 ~ -0.099 | |||||||
Working Pressure | MPa | ≤0.2 | |||||||
Temperature Range | ℃ | 20 ~ 80 | |||||||
Power |
| Three Phase 50Hz380V (according customer requirement) | |||||||
Working Noise | dB(A) | 75 | 75 | 75 | 80 | 80 | 80 | 80 | |
Heating Power | KW | 27 | 30 | 45 | 60 | 75 | 90 | 120 | |
Total Power | KW | 30 | 37.5 | 52.5 | 71.4 | 86.5 | 102.5 | 135 | |
Inlet/Outlet | mm | φ25 | φ32 | φ42 | φ50 | φ50 | φ60 | φ60 | |
Weight | Kg | 450 | 700 | 1050 | 1400 | 1800 | 2000 | 2200 | |
Overall Dimension | Length | mm | 1250 | 1400 | 1640 | 1800 | 2000 | 2050 | 2500 |
Width | mm | 900 | 1050 | 1200 | 1350 | 1450 | 1500 | 1800 | |
Height | mm | 1700 | 1990 | 2000 | 2000 | 2100 | 2100 | 2400 |
Oil Data after Treatment
Moisture (water content) | ≤ 3 PPM |
Gas Content | ≤0.1% |
Impurities Degree (Filtration precision) | ≤1u (without free carbon) |
Breakdown Voltage (Dielectric) | ≥80 KV |
PH value | ≥5.5 |
Acid Value | ≤0.03 mg koH/g |
Dielectric Loss Factors | tgδ (90℃) % ≤0.001 |
Cleanliness | ≤NAS 1638 Grade 6 |
|