Price : | Price Negotiable |
Quantity : | 1000 () |
Minimum Order : | 100 |
Product Status : | New |
Sample Available : | yes |
Payment Mode : |
Bank Transfer |
Categories : | Electrical & Electronics, Electronic Instrument |
Posted By : | Zhejiang Dfh Energy Technology Co.,ltd |
1 Product Brief Introduction
D86 series three-phase watt-hour meter is an induction meter, which is applicable to measure the rated frequency 50Hz and power loss of active and reactive energy meter. The series active energy meter are completely conformed to National Standard GB/T15283-94 Class 0.5、1 and 2 AC Active Watt-hour Meter and International Standard IEC521.All technical targets of reactive meter are completely conformed to National Standard GB/T15282-94 Reactive Watt-hour Meter and International Standard IEC521.
2 Function and Features
-Sub-closed iron core
-the die-casting frame is made of alloy aluminum, to assure the magnetic line stably and reliably.
-Meter bearing has three kinds, may select dual jewel, magnetic thrust or magnetic float;
-May select 5+1 digits or 6 digits register;
-May select 5 kinds of cases; Bakelite, PC, ABS plastic, glass and Aluminum.
3 Main Technical Dates
Name Type Accuracy Rated voltage (V) Rated Current (A) Connection Mode
Three-phase Four-wire Active Watt-hour Meter
DT862 DT864 2 1 3×220/380 3×57.7/100
3×1(2), 3×3(6), 3×1.5(6) 3×5(20), 3×10(40), 3×15(60), 3×20(80), 3×30(100)
3×1(2), 3×3(6), 3×1.5(6)
Input through current transformer Directly Input Input though current voltage transformer
Three-phase Three-wire Active Watt-hour Meter
DS862 DS864 2 1 3×380 3×100 3×380 3×100
3×1(2), 3×3(6), 3×1.5(6) 3×5(20), 3×10(40), 3×15(60), 3×20(80), 3×30(100)
3×1(2), 3×3(6), 3×1.5(6) 3×1(2), 3×3(6), 3×1.5(6) 3×1(2), 3×3(6), 3×1.5(6)
Input through current transformer Directly Input Input though current voltage transformer
Input through current transformer Input though current voltage transformer
Three-phase Four-wire Reactive Watt-hour Meter
DX862 DX864 3 2 3×380 3×100 3×380 3×100
3×1(2), 3×3(6), 3×1.5(6) 3×1(2), 3×3(6), 3×1.5(6)
3×1(2), 3×3(6), 3×1.5(6) 3×1(2), 3×3(6), 3×1.5(6)
Input through current transformer Input though current voltage transformer
Input through current transformer Input though current voltage transformer
Three-phase Three-wire Reactive Watt-hour Meter
DX865 DX863 3 2 3×380 3×100 3×380 3×100
3×1(2), 3×3(6), 3×1.5(6) 3×1(2), 3×3(6), 3×1.5(6)
3×1(2), 3×3(6), 3×1.5(6) 3×1(2), 3×3(6), 3×1.5(6)
Input through current transformer Input though current voltage transformer
Input through current transformer Input though current voltage transformer
![]() |
|