Z125w Ultraviolet Lamp, Fluorescent Lamp

Price : 360.00
Quantity : 500 (set/unit)
Minimum Order : 1
Product Status : New
Sample Available : no
Shipment Terms : fob
Payment Mode : T/T,cash
Categories : Electrical & Electronics, Electric Panel & Cabinet, Electronic Instrument, Machinery, Analysis Instrument, Boiler & Furnace
Posted By :

Jining Luke Testing Equipment Co., Ltd

Description

Z125W ultraviolet lamp, fluorescent lamp

Product information

Z125W ultraviolet lamp, fluorescent lamp, also called fluorescent detection lamp or black lights. After uses ballast to barretter the 220V ac voltage, it provide the whole constant working power for ultraviolet light, produce 315-400m wavelength black light, so as to the inspection of fluorescent powder or fluorescence penetrant flaw. It is a kind of fluorescent detection equipment whose weight is the smallest, the lightest.

Main technical indices:

1. Power: 220V, 50HZ 2. Weight: 5Kg

3. Dimension: 255(width)×105(high)×165(Length) 4.Ultraviolet spectrum : 315-400nm

Method of use:

1. Power cable and lamp output cables connect the instrument panel’s socket.

2. Power is connected 220V power, and the power must be reliable grounding.

3. Turn on the power switch, the power supply voltage has 220V voltage indicator, after all the ultraviolet lamp completely bright, you can detect fluorescent powder flaw.

4. When stop using, shut off the instrument switch, and supply power

Note:

1. Detailed read the instructions before use this device, understanding instrument structure and technical performance, check whether the power meet the request, correctly connected, then you can turn on the power.

2. Before the first or long stock using, you should check whether the instrument is well.

3. When you work, do not continuous repeat switching power supply.

4. Before use, you should check whether the power supply voltage meet the instrument request, neither too high nor too low affects fluorescence detection.

5. This instrument has good temperature protection, when not use, should try to avoid unnecessary load work.

6. Instruments and accessories shall be use or storage in a clean, dry, non-corrosive environment.

Maintenance:

1. After connect the electricity, no indicate, no work, fuse fusing. Because of the short circuit or overload.

2. After the power is connected to indicator work, ultraviolet light not work, bright lights burn or the main circuit and control circuit is failure.

3. Work indicator work, ultraviolet light work, no work instructions, caused by light.

4. When you repair by yourself, please pay attention to machine pressure danger.

Trade References - Contact Us - About Us - Partners - Success Stories - FAQ - Privacy Policy - - English