3.6-35kv Xlpe Insulated Power Cable

Price : 2000.00
Quantity : 10000 (meter)
Minimum Order : 1000
Product Status : New
Sample Available : yes
Shipment Terms : fob,cfr,cif,Negotiable
Payment Mode : T/T,L/C
Categories : Electrical & Electronics, Optical Fiber, Cable & Wire, Electric Wire & Cable, Other Wire & Cable
Posted By :

Guangdong Shuangli Cable Co., Ltd

Description

一、Standards
The cable meets the standard requirements of GB/T12706-2002 or IEC60502-1997. It is suitable to be installed in the power line with rated voltage from U0/U(Um) of 3.6/6(7.2)kV to 26/35(40.5)kV.

二、Type, Designation and Applications

Type

Designation

Applications

YJV
YJLV


Cu or Al conductor XLPE insulated PVC sheathed power cable


For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.

YJV22
YJLV22

Cu or Al conductor XLPE insulated PVC sheathed internal steel tape armored power cable

Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces.

三、Specifications

Type


Number of cores

U0/U(Um) Rated Voltage

3.6/6(7.2) 6/6(7.2)

6/10(12) 8.7/10(12)

8.7/15(17.5) 12/20(24)

18/30(36) 26/35(40.5)

Nominal Cross-sectional Area (mm2)

YJV
YJV22

1

35-630

35-630

35-630

50-630

YJLV
YJLV22

1

35-630

35-630

35-630

50-630

YJV
YJV22

3

35-300

35-300

35-300

YJLV
YJLV22

3

25-300

25-300

25-300


四、Structure Drawing
Conductor
Inner semi-conductor screen
Insulation
Soft copper tape
Binder
Outer-sheath

Filler
Conductor
Inner semi-conductor screen
Insulation
Soft copper tape
Binder
Under-sheath
Steel tape
Outer-sheath


Filler
Conductor
Inner semi-conductor screen
Insulation
Soft copper tape
Binder
Under-sheath
Steel wire
Outer-sheath


五、Using properties
Earth fault permissible duration
The operating systems are divided into three categories available for selecting cable.
Category A: When any phase is earthed, the cable can be departed from the system within 1 minute.
Category B:The earth fault duration each time does not exceed one hour, the accumulated time shall not exceed 125 hours each year.
Category C: Excluded categories from A and B.

Rated voltage of cable for three-phase system


Um/kV
The maximum voltage vales for the system (Um/kV)

U0/kV

Category A
Category B

Category C

7.2

3.6

6.0

12.0

6.0

8.7

17.5

8.7

12.0

24.0

12.0

18.0

36.0

18.0

2、The maximum rated temperature
The maximum operating temperature of cores shall not exceed 90℃ when the cable is used for long period. The temperature of cores shall not exceed 250℃ at short circuit for 5 seconds.

3、Installation requirement

The installation of cables is not limited by the difference of level along the route. The ambient temperature should not be below 0℃ during installation. The permissible bending radius for cable shall not be less than 10 times of the cable diameter. The single cable shall be without amour or with steel wire amour when it is electrified with alternating current and shall not be laid in magnetic ducts.

六、Technical specifications


七、Technical parameters
3.6/6(7.2)kV XLPE insulated power cable (single core)

3.6/6(7.2)kV XLPE insulated power cable (three cores)

6/6(7.2)kV & 6/10(12)kV XLPE insulated power cable (single core)

6/6(7.2)kV & 6/10(12)kV XLPE insulated power cable (three cores)

8.7/10(12)kV & 8.7/15(17.5)kV XLPE insulated power cable (single core)

8.7/10(12)kV & 8.7/15(17.5)kV XLPE insulated power cable (three cores)

12/20(24)kV XLPE insulated power cable (single core)

8.7/10(12)kV XLPE insulated power cable (three cores)

18/30(36)kV XLPE insulated power cable (single core)

21/35(40.5)kV XLPE insulated power cable (single core)

26/35(40.5)kV XLPE insulated power cable (single core)


八、Flame Retardant XLPE cable
The electric properties of flame retardant XLPE cable are the same as those of ordinary XLPE cable. The combustion property of flame retardant cable complies with category A, B, C of bunched burning according to GB1266-90 (equivalent to IEC332-3). The construction and dimension are identical with ordinary XLPE cable except cables of ZRA-YJV and ZRA-YJLV. The flame retardant PVC is used as the inner covering and the sheath of cable.
Type of flame retardant XLPE cable:
Category A: ZRA-YJV、ZRA-YJLV、ZRA-YJV22、ZRA-YJLV22
Category B: ZRB-YJV、ZRB-YJLV、ZRB-YJV22
Category C: ZR-YJV、ZR-YJLV、ZR-YJV22、ZRA-YJLV22

九、The circumstance temperature is 40℃ in the air. The thermal resistivity of soil is 100℃cm/w.


In the Air


Voltage Level

3.6/6(7.2)~12/20(24) kV

18/30(36)~26/35(40.5)kV

6/6(7.2)~12/20(24)kV

Arrangement

Nominal Cross-sectional Area of Copper Conductor(mm2)

Current Capacity (A)

25

140

165

-

-

120

35

170

205

-

-

140

50

205

245

220

245

165

70

260

305

270

305

210

95

315

370

330

370

255

120

360

430

375

425

290

150

410

490

425

485

330

185

470

560

485

555

375

240

555

665

560

650

435

300

640

765

650

745

405

400

745

890

760

870

-

500

855

1030

875

1000

-

630

980

1190

1000

1160

-

Nominal Cross-sectional Area of Aluminum Conductor(mm2)

Current Capacity (A)

25

110

130

-

-

90

35

135

155

-

-

110

50

160

190

170

190

130

70

200

235

210

235

165

95

245

290

255

285

200

120

280

335

290

330

225

150

320

380

330

375

255

185

365

435

380

430

295

240

435

515

435

505

345

300

500

959

510

580

390

400

585

695

595

680

-

500

680

810

690

790

-

630

790

950

800

920

-


In the Soil

Voltage Level

3.6/6(7.2)~12/20(24) kV

18/30(36)~26/35(40.5)kV

6/6(7.2)~12/20(24)kV

Arrangement

Nominal Cross-sectional Area of Copper Conductor(mm2)

Current Capacity (A)

25

150

160

-

-

125

35

180

190

-

-

155

50

215

225

215

225

180

70

265

275

265

275

220

95

315

330

315

330

265

120

360

375

360

375

300

150

405

425

400

420

340

185

455

480

455

475

380

240

530

555

525

555

435

300

595

630

595

630

485

400

680

725

680

720

-

500

765

825

775

825

-

630

860

940

875

940

-

(mm2)
Nominal Cross-sectional Area of Aluminum Conductor

Current Capacity (A)

25

115

120

-

-

100

35

135

145

-

-

120

50

160

175

165

175

140

70

200

215

200

215

170

95

240

255

240

255

210

120

270

295

270

290

235

150

305

330

305

325

260

185

345

370

345

370

300

240

400

435

400

430

345

300

455

490

455

490

390

400

520

565

525

565

-

500

595

650

600

645

-

630

680

745

685

740

-

Trade References - Contact Us - About Us - Partners - Success Stories - FAQ - Privacy Policy - - English
2013-2024 ©TCNTCN.COM 鲁ICP备13021038号-3