Price : | Price Negotiable |
Minimum Order : | 1 (set) |
Product Status : | New |
Sample Available : | yes |
Shipment Terms : | fob,Negotiable |
Payment Mode : |
T/T,Negotiable |
Categories : | Electrical & Electronics, Electronic Instrument, Transducer |
Posted By : | Ainuo Instrument Co., Ltd. |
Technical Characteristics
◆Compliant with IEC60335-1, GB4706 standard requirements
◆Large blue LCD display with key parameters displayed in large font size
◆Smart judgment in large window and alarm function
◆Supports both Chinese and English, simple and convenient operations
◆User limitation verification, with 8 programmable groups
◆Rise-time control function
◆Upper and lower limit alarm, open and short circuit alarm protection
◆Automatic high speed test, auto-shift function
Technical Characteristics
◆Compliant with IEC60335-1, GB4706 standard requirements
◆Large blue LCD display with key parameters displayed in large font size
◆Smart judgment in large window and alarm function
◆Supports both Chinese and English, simple and convenient operations
◆User limitation verification, with 8 programmable groups
◆Rise-time control function
◆Upper and lower limit alarm, open and short circuit alarm protection
◆Automatic high speed test, auto-shift function
Model | AN9636H(F) | |||
AC Hipot Test | Output Voltage Setting / Test Range | 100V~5000V AC 100mA 1V/step | ||
Output Voltage Adjustments | ±(2% of setting+5V) | |||
Output Voltage Resolution/ Accuracy | 10V, ±(2% of setting+5V) | |||
Output Frequency Range/ Accuracy | 50Hz/60Hz, ±100ppM | |||
Output Voltage Waveform | Sine wave for pure resistive load , > 200V, distortion | |||
Breakdown Current Alarm Upper and Lower Limit Setting Range | Upper Limit: 0.00~99.99mA, 0.01mA/step | |||
Breakdown Current Range | 0.000~3.500mA/3.50~99.99mA | |||
Breakdown Current Resolution | 0.001mA/0.01mA | |||
Breakdown Current Accuracy | < ±(2% of reading+3counts) | |||
Rise Time /Fall time/Test Time Range | 0.0~999.9s/0.0~999.9s 0.1s/step | |||
Offset Cancellation Function | 0~2.000mA, auto or manual offset compensation | |||
DC Hipot Test | Output Voltage Setting and Range | 100V~6000V DC 10mA 1V/step | ||
Output Voltage Regulated Rate | ±(2% of setting+5V) | |||
Resolution and Accuracy | 10V, ±(2% of setting+5V) | |||
DC Ripple Quotient | No load≤2%, Full load≤5%(under 6kV DC/10mA) | |||
Breakdown Current Alarm Upper and Lower Limit Setting Range | Upper Limit 0.0~9999μA, 1μA/step | |||
Upper//Low Limit Setting Range of DC Rising Current | 12mA, ON / OFF Optional / 0.0~350.0μA | |||
Breakdown Current Measurement Range | 0.0~350.0μA /300~3500μA/3.00~9.99mA | |||
Breakdown Current Measurement Resolution & Accuracy | 0.1μA /1μA /0.01mA | |||
Rise-Time Setting and Measurement Time Range | 0.0~999.9s/0.5~999.9s 0.1s/step | |||
Offset Cancellation Function | 0~200μA, auto or manual offset compensation | |||
Insulation Resistance Test | Output Voltage Setting and Range | 100V~1000V DC 1V/step | ||
Output Voltage Resolution and Accuracy | 1V, ±(2% of setting+5V) | |||
DC Ripple Quotient | No load≤1% , Full Load | |||
Output Voltage Regulated Rate | ±(2% of setting+5V) | |||
Test time Setting Range | 0.5~999.9s 0.1s/step | |||
Lower limit Setting Range of Insulation Resistance | 1~9999M | |||
Upper limit Setting Range of Insulation Resistance | 0~9999M | |||
Lower Limit Setting Range of DC Charging Current | 0.000~3.500μA | |||
Insulation Resistance Range | 1~9999M, automatic gear shift, 4 digit display | 1~2000M, automatic gear shift, 4 digit display | ||
Insulation Resistance Measurement Accuracy | 500~1000V: ±(2% of reading+2counts)1~200M; | 500~1000V: ±(2% of reading+2counts)1~200M; | ||
Dimension(W×H×D) (mm) | Desktop Style:400×156×475 |
|